Executive standard | JB/T 9248-1999 |
Nominal diameter | 15-2000mm |
Velocity range | 0-10m/s |
Degree of accuracy | ±0.5%R,±1%R(<DN20 ) |
Medium conductivity | ≥5uS/cm,Actual conductivity≥30uS/cm |
Nominal pressure | 1.0MPa | 1.6MPa | 2.5MPa | 4.0MPa |
DN15-DN800 | DN15-DN800 | DN15-DN600 | DN15-DN50 |
Environment temperature | Sensor | 0℃ - +80℃ or -25℃ - +120℃ or +70-+250℃ |
Incorporate type | -10℃ - +55℃ |
Highest medium temperature | Incorporate type | +80℃ |
Separate body-type | CR chloroprene rubber liner (CR) | +80℃ |
Polytetrafluoroethylene lining(F4) | +120℃ |
Politef lining(F46) |
Teflon(PFA) | +180℃ |
Fluorosilicone rubber(FVMQ) | +250℃ |
Output signal | 4-20mA;Pulse/Frequency 2kHz(Default),5KHz(Max) |
Cable entry size | M20 × 1.5 (Standard nylon waterproof connector, optional explosion-proof metal connector) |
Supply voltage | 110/220VAC(100-240VAC),50Hz/60Hz;24VDC ±10% |
Power dissipation | ≤15VA |
Digital communication | RS-485,Support standard Modbus-RTU protocol;GPRS |
Signal electrode and the ground electrode material | Stainless steel 316L,Hastelloy C,Hastelloy B,titanium, tantalum, platinum |
Form of electric pole | Interpolating, extrapolating electrode need to customize |
Number of electrodes | Standard configuration 3-4 electrodes (two measuring electrodes plus a grounding electrode), according to the caliber configuration |
Flange Standard | Conform to the international GB9119 ( customize according to customer's demand) |
Connecting flange material | Standard carbon steel and stainless steel are needed to be customized |
Grounding ring material | Stainless steel, and stainless steel that contains molybdenum, etc. |
DN15-DN450 | Stainless steel 1Cr18Ni9Ti(Ordinary austenitic stainless steel SUS321) |
Housing material | Standard carbon steel and stainless steel are needed to be customized |
Level of protection | Separate body-type | IP68、IP65 |
Incorporate type | IP65 |
Interval / wire length (Separate body-style) | 10m standard configuration connecting line, optional 15m, 20m, 25m, 30m. |
Ordering instruction
The following questions should be clear when selects the electromagnetic flow meter :
(1) The medium to be measured must be conductive fluid, and it isn't available to the gas, oil, organic solvents and the non-conductive medium.
(2) When selects the model and specification, we should provide the measurement range of the electromagnetic flowmeter for the manufacturer, then the factory should make a demarcation within the scope of this measure in order to ensure accuracy of the instrument.
(3) The users should provide manufacturers with the medium's process parameters, flow rate and temperature, pressure and other parameters of the selection table, then based on these parameters, select the appropriate meter.
(4) When selects the separate body-type electromagnetic flow meter, the users should propose wiring length requirements to the factory according to the sensor distance away from installation location of converter.
(5) If users need to install accessories, such as supporting flange, metal ring gasket, bolts, nuts, washers and other additional requirements, they can put them forward when ordering.